Inventis CLARINET

Clarinet is a clinical middle ear analyzer, featured with all the tests needed for a deep and accurate investigation of middle ear disorders. Automatic and manual tympanometry, acoustic reflex threshold, decay and latency examinations, ETF for intact and perforated eardrums, high frequency and multi-component tympanometry are all available and full results can be observed on a wide color touch screen display. 

The DISPLAY: 

Clarinet incorporates a large high-resolution color graphic display, giving a clear and detailed picture of the exam in progress. And with touch screen input, interaction with the instrument is extremely simple.

 

GSI Tympstar

Grace and Stadler Instruments Clinical Tympanometer

The GSI Tympstar full function clinical tympanometer

The GSI TympStar sets the standard for clinical middle-ear testing… a standard that had been established by its predecessor, the GSI 33. The sophistication, functionality and flexibility of the GSI TympStar provides unparalleled testing capabilities. The GSI TympStar Version 1 provides four different test modes: tympanometry, reflex threshold, reflex decay, and Eustachian tube function testing. Move up to the Version 2 if you are interested in accurately testing newborns and differential diagnosis of middle ear problems using multiple component and multi-frequency tympanometry. ( BC customers only)

 

 

 

Middle Ear Analyzer MI 34

MI 34 Middle Ear Analyzer

The Maico MI 34 Middle Ear Analyzer is a popular and affordable choice

MI 34 H with 1000 Hz High Frequency Probe Tone; Fast, automatic tests – Tympanogram in 3 seconds; Ipsi- and contralateral reflex tests with 4 frequencies; Reflex Decay Test; Eustachian tube function test for intact and perforated eardrums; Handheld, adjustable probe for diagnostic and screening purposes; Graphical realtime display; Fast, virtually silent printout of test results

Middle Ear Analyzer MI 44

the Maico MI 44 Middle Ear Analyzer

The Maico MI 44 Middle Ear Analyzer with High Frequency Tympanometry is a good choice for Infant Screening Programs

 

 

Manual and automatic pump control; Tympanometry with selectable pressure ranges and pump speeds; Ipsi- and contralateral reflex tests – now with tone and noise; Reflex decay test and ETF Test for intact and perforated eardrums; High Frequency Probe Tones: 678 Hz, 800 Hz, 1000 Hz; Exchangeable probe insert for screening and diagnostic use; USB PC interface

 

 

 

 

 

 

 

( dB ) Special Instruments for Hearing Testing

AIM Instrumentation’s original Corporate Logo and Slogan

 

 