Portable Thermal Environment Monitors
simultaneously monitor and protect groups of workers.
Personal Heat Stress Monitors measure and detect the physiological responses to heat stress of an individual.
QUESTemp° 32 Portable Monitor
Features: Real-Time Readings for Wet/Dry Bulb, Globe, WBGT Indoor/Outdoor, Relative Humidity and Heat Index Optional Remote Sensors for up to (3) Simultaneously Monitored Areas
QUESTemp° 34 Portable Monitor
Features: All QT32° Features Plus Humidex/Heat Index Reading Data Logging
QUESTemp° 36 Portable Monitor
Features: All QT34° Features Plus Calculates and Displays Stay Time Data Optional Air Probe Provides Air Speed Data
QUESTemp° 44 Portable Monitor
Features: Waterless Wet Bulb
QUESTemp° 46 Portable Monitor
Features: Waterless Wet Bulb Optional Air Probe Provides Air Speed Data
QUESTemp° II Personal Monitor
Features: Belt Worn Personal Heat Stress Monitor Monitors Core Body Temperature
Feature Matrix
| Specifications | QUESTemp° 34 Portable Monitor | QUESTemp° 36 Portable Monitor | QUESTemp° II Personal Monitor |
|---|---|---|---|
| Datalogging Intervals | 1, 2, 5, 10, 15, 30 or 60 Minutes | 1, 2, 5, 10, 15, 30 or 60 Minutes | Fixed at 10 Seconds |
| Relative Humidity Range | 0 to 100% | 0 to 100% | — |
| Standards\Approvals | Intrinsic Safety: UL/CSA Standards for Class i, Groups A, B,C & D; Groups E, F & G; Class. Temperature Code T3 & European Standards for EEX ia IIC, T3 Electromagnetic Conformance: |
Intrinsic Safety: UL/CSA Standards for Class i, Groups A, B,C & D; Groups E, F & G; Class. Temperature Code T3 & European Standards for EEX ia IIC, T3 Electromagnetic Conformance: |
Intrinsic Safety: UL/CSA Standards for Class i, Groups A, B,C & D; Groups E, F & G; Class. Temperature Code T3 & European Standards for EEX ia IIC, T3 Electromagnetic Conformance: |
| Temperature Range | -5 to 100C (23 to 212F) | -5 to 100C (23 to 212F) | 32 to 40C (90 to 104F) |
| Outputs | RS232 Serial Computer/Printer Interface Parallel Printer Interface |
RS232 Serial Computer/Printer Interface Parallel Printer Interface |
RS232 Serial Computer/Printer Interface |
| Size | 9.2 x 7.2 x 3″ (23.5 x 18.3 x 7.5 mm) | 9.2 x 7.2 x 3″ (23.5 x 18.3 x 7.5 mm) | 5.1 x 2.5 x 1″ (64 x 130 x 25 mm) |
| Weight | 2.6 lbs (1.2 kg) | 2.6 lbs (1.2 kg) | 10 oz (283 g) |
| DataLogging | Time History Profile for all Displayed Parameters | Time History Profile for all Displayed Parameters | Summary and Time History |
| Inputs | RTD Temperature Sensor Capacitive Polymer Relative Humidity Sensor |
RTD Temperature Sensor Capacitive Polymer Relative Humidity Sensor Hot Wire Air Velocity Sensor |
Thermistor Temperature Sensor |
| Available Options | Optional Remote Sensors for up to (3) simultaneously monitored areas | Optional Remote Sensors for up to (3) simultaneously monitored areas Hot Wire Air Velocity Sensor |
— |
| Available Measurements | Celsius and Fahrenheit Scales Wet Bulb Dry Bulb Globe WBGT Indoor WBGT Outdoor Relative Humidity Heat Index Humidex |
Celsius and Fahrenheit Scales Wet Bulb Dry Bulb Globe WBGT Indoor WBGT Outdoor Relative Humidity Heat Index Humidex Air Flow |
Celsius and Fahrenheit Scales Temperature |
| Case\Housing | Aluminum | Aluminum | Aluminum |
| Power Source | 9V Disposable Batteries (150 Hrs.) NiMH Rechargeable Option (300 Hrs.) AC Power Adapter |
9V Disposable Batteries (150 Hrs.) NiMH Rechargeable Option (300 Hrs.) AC Power Adapter |
9V Disposable Batteries (60 Hrs.) |
| QSP Compatible | — | — | Yes |
| QSP II Compatible | Yes | Yes | — |
| Air Velocity Range | — | 0 to 20 m/s | — |
| Stay Time/Work Rest Cycles | — | ACGIH TLV Handbook U.S. Navy PHEL Charts EPRI Action Limits. |
— |